You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
SMX_PGE/smx-config/ConfigPresets.cs

149 lines
6.9 KiB

using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace smx_config
{
class ConfigPresets
{
static private string[] Presets = { "low", "normal", "high" };
static public string GetPreset(SMX.SMXConfig config)
{
// If the config we're comparing against is a V1 config, that means the per-panel thresholds
// weren't set and those fields are ignored (or not supported by) by the firmware. Sync those
// thresholds to the unified thresholds before comparing. That way, we'll correctly match up
// each preset regardless of what happens to be in the unused per-panel threshold fields.
// If we don't do this, we won't recognize that the default preset is active because unused
// fields won't match up.
if(config.configVersion == 0xFF || config.configVersion < 2)
SyncUnifiedThresholds(ref config);
foreach(string Preset in Presets)
{
SMX.SMXConfig PresetConfig = SMX.SMXConfig.Create();
SetPreset(Preset, ref PresetConfig);
if(SamePreset(config, PresetConfig))
return Preset;
}
return "";
}
// Return true if the config matches, only comparing values that we set in presets.
static private bool SamePreset(SMX.SMXConfig config1, SMX.SMXConfig config2)
{
for(int panel = 0; panel < 9; ++panel)
{
if(config1.panelSettings[panel].loadCellLowThreshold != config2.panelSettings[panel].loadCellLowThreshold ||
config1.panelSettings[panel].loadCellHighThreshold != config2.panelSettings[panel].loadCellHighThreshold)
return false;
for(int sensor = 0; sensor < 4; ++sensor)
{
if(config1.panelSettings[panel].fsrLowThreshold[sensor] != config2.panelSettings[panel].fsrLowThreshold[sensor] ||
config1.panelSettings[panel].fsrHighThreshold[sensor] != config2.panelSettings[panel].fsrHighThreshold[sensor])
return false;
}
}
return true;
}
static public void SetPreset(string name, ref SMX.SMXConfig config)
{
switch(name)
{
case "low": SetLowPreset(ref config); return;
case "normal": SetNormalPreset(ref config); return;
case "high": SetHighPreset(ref config); return;
}
}
static private void SetPreset(ref SMX.SMXConfig config,
byte loadCellLow, byte loadCellHigh, byte loadCellLowCenter, byte loadCellHighCenter,
byte fsrLow, byte fsrHigh, byte fsrLowCenter, byte fsrHighCenter)
{
for(int panel = 0; panel < 9; ++panel)
{
config.panelSettings[panel].loadCellLowThreshold = loadCellLow;
config.panelSettings[panel].loadCellHighThreshold = loadCellHigh;
}
// Center:
config.panelSettings[4].loadCellLowThreshold = loadCellLowCenter;
config.panelSettings[4].loadCellHighThreshold = loadCellHighCenter;
for(int panel = 0; panel < 9; ++panel)
{
for(int sensor = 0; sensor < 4; ++sensor)
{
config.panelSettings[panel].fsrLowThreshold[sensor] = fsrLow;
config.panelSettings[panel].fsrHighThreshold[sensor] = fsrHigh;
}
}
// Center:
for(int sensor = 0; sensor < 4; ++sensor)
{
config.panelSettings[4].fsrLowThreshold[sensor] = fsrLowCenter;
config.panelSettings[4].fsrHighThreshold[sensor] = fsrHighCenter;
}
}
static private void SetHighPreset(ref SMX.SMXConfig config)
{
SetPreset(ref config,
20, 25, 20, 30,
140, 150, 140, 160);
}
static private void SetNormalPreset(ref SMX.SMXConfig config)
{
SetPreset(ref config,
33, 42, 35, 60,
162, 175, 202, 225);
}
static private void SetLowPreset(ref SMX.SMXConfig config)
{
SetPreset(ref config,
70, 80, 100, 120,
200, 219, 212, 225);
}
// The simplified configuration scheme sets thresholds for up, center, cardinal directions
// and corners. Rev1 firmware uses those only. Copy cardinal directions (down) to the
// other cardinal directions (except for up, which already had its own setting) and corners
// to the other corners.
static public void SyncUnifiedThresholds(ref SMX.SMXConfig config)
{
// left = right = down (cardinal)
config.panelSettings[3].loadCellLowThreshold = config.panelSettings[5].loadCellLowThreshold = config.panelSettings[7].loadCellLowThreshold;
config.panelSettings[3].loadCellHighThreshold = config.panelSettings[5].loadCellHighThreshold = config.panelSettings[7].loadCellHighThreshold;
// UL = DL = DR = UR (corners)
config.panelSettings[0].loadCellLowThreshold = config.panelSettings[6].loadCellLowThreshold = config.panelSettings[8].loadCellLowThreshold = config.panelSettings[2].loadCellLowThreshold;
config.panelSettings[0].loadCellHighThreshold = config.panelSettings[6].loadCellHighThreshold = config.panelSettings[8].loadCellHighThreshold = config.panelSettings[2].loadCellHighThreshold;
// Do the same for FSR thresholds.
for(int sensor = 0; sensor < 4; ++sensor)
{
config.panelSettings[3].fsrLowThreshold[sensor] = config.panelSettings[5].fsrLowThreshold[sensor] = config.panelSettings[7].fsrLowThreshold[sensor];
config.panelSettings[3].fsrHighThreshold[sensor] = config.panelSettings[5].fsrHighThreshold[sensor] = config.panelSettings[7].fsrHighThreshold[sensor];
config.panelSettings[0].fsrLowThreshold[sensor] = config.panelSettings[6].fsrLowThreshold[sensor] = config.panelSettings[8].fsrLowThreshold[sensor] = config.panelSettings[2].fsrLowThreshold[sensor];
config.panelSettings[0].fsrHighThreshold[sensor] = config.panelSettings[6].fsrHighThreshold[sensor] = config.panelSettings[8].fsrHighThreshold[sensor] = config.panelSettings[2].fsrHighThreshold[sensor];
}
}
// Return true if the panel thresholds are already synced, so SyncUnifiedThresholds would
// have no effect.
static public bool AreUnifiedThresholdsSynced(SMX.SMXConfig config)
{
SMX.SMXConfig config2 = Helpers.DeepClone(config);
SyncUnifiedThresholds(ref config2);
return SamePreset(config, config2);
}
}
}