using System;
|
|
using System.Collections.Generic;
|
|
using System.Linq;
|
|
using System.Text;
|
|
using System.Threading.Tasks;
|
|
|
|
namespace smx_config
|
|
{
|
|
class ConfigPresets
|
|
{
|
|
static private string[] Presets = { "low", "normal", "high" };
|
|
|
|
static public string GetPreset(SMX.SMXConfig config)
|
|
{
|
|
// If the config we're comparing against is a V1 config, that means the per-panel thresholds
|
|
// weren't set and those fields are ignored (or not supported by) by the firmware. Sync those
|
|
// thresholds to the unified thresholds before comparing. That way, we'll correctly match up
|
|
// each preset regardless of what happens to be in the unused per-panel threshold fields.
|
|
// If we don't do this, we won't recognize that the default preset is active because unused
|
|
// fields won't match up.
|
|
if(config.configVersion == 0xFF || config.configVersion < 2)
|
|
SyncUnifiedThresholds(ref config);
|
|
|
|
foreach(string Preset in Presets)
|
|
{
|
|
SMX.SMXConfig PresetConfig = config;
|
|
SetPreset(Preset, ref PresetConfig);
|
|
if(SamePreset(config, PresetConfig))
|
|
return Preset;
|
|
}
|
|
return "";
|
|
}
|
|
|
|
// Return true if the config matches, only comparing values that we set in presets.
|
|
static private bool SamePreset(SMX.SMXConfig config1, SMX.SMXConfig config2)
|
|
{
|
|
// These aren't arrays for compatibility reasons.
|
|
if( config1.panelThreshold0High != config2.panelThreshold0High ||
|
|
config1.panelThreshold1High != config2.panelThreshold1High ||
|
|
config1.panelThreshold2High != config2.panelThreshold2High ||
|
|
config1.panelThreshold3High != config2.panelThreshold3High ||
|
|
config1.panelThreshold4High != config2.panelThreshold4High ||
|
|
config1.panelThreshold5High != config2.panelThreshold5High ||
|
|
config1.panelThreshold6High != config2.panelThreshold6High ||
|
|
config1.panelThreshold7High != config2.panelThreshold7High ||
|
|
config1.panelThreshold8High != config2.panelThreshold8High)
|
|
return false;
|
|
if( config1.panelThreshold0Low != config2.panelThreshold0Low ||
|
|
config1.panelThreshold1Low != config2.panelThreshold1Low ||
|
|
config1.panelThreshold2Low != config2.panelThreshold2Low ||
|
|
config1.panelThreshold3Low != config2.panelThreshold3Low ||
|
|
config1.panelThreshold4Low != config2.panelThreshold4Low ||
|
|
config1.panelThreshold5Low != config2.panelThreshold5Low ||
|
|
config1.panelThreshold6Low != config2.panelThreshold6Low ||
|
|
config1.panelThreshold7Low != config2.panelThreshold7Low ||
|
|
config1.panelThreshold8Low != config2.panelThreshold8Low)
|
|
return false;
|
|
return true;
|
|
}
|
|
|
|
static public void SetPreset(string name, ref SMX.SMXConfig config)
|
|
{
|
|
switch(name)
|
|
{
|
|
case "low": SetLowPreset(ref config); return;
|
|
case "normal": SetNormalPreset(ref config); return;
|
|
case "high": SetHighPreset(ref config); return;
|
|
}
|
|
}
|
|
|
|
static private void SetHighPreset(ref SMX.SMXConfig config)
|
|
{
|
|
config.panelThreshold7Low = // cardinal
|
|
config.panelThreshold1Low = // up
|
|
config.panelThreshold2Low = 20; // corner
|
|
config.panelThreshold7High = // cardinal
|
|
config.panelThreshold1High = // up
|
|
config.panelThreshold2High = 25; // corner
|
|
|
|
config.panelThreshold4Low = 20; // center
|
|
config.panelThreshold4High = 30;
|
|
SyncUnifiedThresholds(ref config);
|
|
}
|
|
|
|
static private void SetNormalPreset(ref SMX.SMXConfig config)
|
|
{
|
|
config.panelThreshold7Low = // cardinal
|
|
config.panelThreshold1Low = // up
|
|
config.panelThreshold2Low = 33; // corner
|
|
config.panelThreshold7High = // cardinal
|
|
config.panelThreshold1High = // up
|
|
config.panelThreshold2High = 42; // corner
|
|
|
|
config.panelThreshold4Low = 35; // center
|
|
config.panelThreshold4High = 60;
|
|
SyncUnifiedThresholds(ref config);
|
|
}
|
|
|
|
static private void SetLowPreset(ref SMX.SMXConfig config)
|
|
{
|
|
config.panelThreshold7Low = // cardinal
|
|
config.panelThreshold1Low = // up
|
|
config.panelThreshold2Low = 70; // corner
|
|
config.panelThreshold7High = // cardinal
|
|
config.panelThreshold1High = // up
|
|
config.panelThreshold2High = 80; // corner
|
|
|
|
config.panelThreshold4Low = 100; // center
|
|
config.panelThreshold4High = 120;
|
|
SyncUnifiedThresholds(ref config);
|
|
}
|
|
|
|
// The simplified configuration scheme sets thresholds for up, center, cardinal directions
|
|
// and corners. Rev1 firmware uses those only. Copy cardinal directions (down) to the
|
|
// other cardinal directions (except for up, which already had its own setting) and corners
|
|
// to the other corners.
|
|
static public void SyncUnifiedThresholds(ref SMX.SMXConfig config)
|
|
{
|
|
// left = right = down (cardinal)
|
|
config.panelThreshold3Low = config.panelThreshold5Low = config.panelThreshold7Low;
|
|
config.panelThreshold3High = config.panelThreshold5High = config.panelThreshold7High;
|
|
|
|
// UL = DL = DR = UR (corners)
|
|
config.panelThreshold0Low = config.panelThreshold6Low = config.panelThreshold8Low = config.panelThreshold2Low;
|
|
config.panelThreshold0High = config.panelThreshold6High = config.panelThreshold8High = config.panelThreshold2High;
|
|
}
|
|
|
|
// Return true if the panel thresholds are already synced, so SyncUnifiedThresholds would
|
|
// have no effect.
|
|
static public bool AreUnifiedThresholdsSynced(SMX.SMXConfig config)
|
|
{
|
|
SMX.SMXConfig config2 = config;
|
|
SyncUnifiedThresholds(ref config2);
|
|
return SamePreset(config, config2);
|
|
}
|
|
}
|
|
}
|
|
|